PREMIUM是专注于电源定制服务的公司。标准的产品涉及DC-DC AC-DC DC-AC。
产品应用于铁路、医疗、智能电网及新能源、半导体设备、激光等特殊行业。
CTS-60 Series
GENERAL FEATURES:
●Designed according to EN50155
●Fire and smoke:EN45545-2 approved
●Switching frequency:140KHz
●High input-output isolation
●Adjustable output voltage
●Remote sensing
●Output voltage presence LED
24Vin 14.4...30V 16.8...30V | 36Vin 21.6...47V 25.2...47V | 48Vin 28.8...60V 33.6...60V | 72Vin 43.2...90V 50.4...90V | 110Vin 66...144V 77...144V | |
5Vout | CTS-60-6835 | CTS-60-6851 | CTS-60-6839 | CTS-60-6843 | CTS-60-6847 |
50W 78% | 50W 78% | 50W 79% | 50W 79% | 50W 80% | |
12Vout | CTS-60-6836 | CTS-60-6852 | CTS-60-6840 | CTS-60-6844 | CTS-60-6848 |
60W 83% | 60W 83% | 60W 84% | 60W 84% | 60W 85% | |
15Vout | CTS-60-6855 | ||||
60W 85% | |||||
24Vout | CTS-60-6837 | CTS-60-6853 | CTS-60-6841 | CTS-60-6845 | CTS-60-6849 |
60W 84% | 60W 84% | 60W 85% | 60W 85% | 60W 85% | |
48Vout | CTS-60-6838 | CTS-60-6854 | CTS-60-6842 | CTS-60-6846 | CTS-60-6850 |
60W 85% | 60W 85% | 60W 85% | 60W 85% | 60W 85% |
CCS-60 Series
GENERAL FEATURES:
●Railway features according to EN50155
●Hold up time 10mS
●Remote inhibit
●High input-output isolation
●Standard size Eurocard 3U
●Adjustable output voltage
●Remote sensing
●Input voltage OK LED
●Output voltage presence LED
12Vin 9.5...15V 9.5...15V | 24Vin 14.4...30V 16.8...30V | 48Vin 28.8...60V 33.6...60V | 72Vin 43.2...90V 50.4...90V | 110Vin 66...144V 77...144V | |
5Vout | CCS-60-6551 | CCS-60-6555 | CCS-60-6559 | CCS-60-6563 | CCS-60-6567 |
50W 77% | 50W 78% | 50W 79% | 50W 79% | 50W 80% | |
12Vout | CCS-60-6552 | CCS-60-6556 | CCS-60-6570 | CCS-60-6564 | CCS-60-6568 |
60W 78% | 70W 83% | 70W 84% | 70W 84% | 70W 85% | |
24Vout | CCS-60-6553 | CCS-60-6557 | CCS-60-6571 | CCS-60-6565 | CCS-60-6569 |
60W 80% | 70W 84% | 70W 85% | 70W 85% | 70W 85% | |
48Vout | CCS-60-6554 | CCS-60-6558 | CCS-60-6572 | CCS-60-6566 | CCS-60-6570 |
60W 82% | 70W 85% | 70W 85% | 70W 85% | 70W 85% |
CRS-60 Series
GENERAL FEATURES:
●Switching frequency:140KHz
●High input-output isolation
●Adjustable output voltage
●Remote sensing
●Output voltage presence LED
12Vin 9.5...15V | 24Vin 18...30V | 48Vin 36...60V | 72Vin 50.4...90V | 110Vin 77...144V | |
5Vout | CRS-60-6731 | CRS-60-6735 | CRS-60-6739 | CRS-60-6743 | CRS-60-6747 |
50W 77% | 50W 78% | 50W 79% | 50 79% | 50W 80% | |
12Vout | CRS-60-6732 | CRS-60-6736 | CRS-60-6740 | CRS-60-6744 | CRS-60-6748 |
60W 78% | 60W 83% | 60W 84% | 60W 84% | 60W 85% | |
24Vout | CRS-60-6733 | CRS-60-6737 | CRS-60-6741 | CRS-60-6745 | CRS-60-6749 |
60W 80% | 60W 84% | 60W 85% | 60W 85% | 60W 85% | |
48Vout | CRS-60-6734 | CRS-60-6738 | CRS-60-6742 | CRS-60-6746 | CRS-60-6750 |
60W 82% | 60 85% | 60W 85% | 60W 85% | 60W 85% |
CRS-120 Series
GENERAL FEATURES:
●Switching frequency:140KHz
●High input-output isolation
●Standard size Eurocard 3U
●Adjustable output voltage
●Remote sensing
●Input voltage OK LED
●Output voltage presence LED
●Remote inhibit
12Vin 9...15V | 24Vin 18...30V | 48Vin 36...72V | 72Vin 50.4...90V | 110Vin 77...144V | 220Vin 165...275V | |
5Vout | CRS-120-6761 | CRS-120-6765 | CRS-120-6769 | CRS-120-6773 | CRS-120-6777 | CRS-120-6781 |
100W 77% | 100W 78% | 100W 79% | 100W 79% | 100W 80% | 100W 80% | |
12Vout | CRS-120-6762 | CRS-120-6766 | CRS-120-6770 | CRS-120-6774 | CRS-120-6778 | CRS-120-6782 |
100 78% | 120W 83% | 120W 84% | 120W 84% | 120W 85% | 120W 85% | |
24Vout | CRS-120-6763 | CRS-120-6767 | CRS-120-6771 | CRS-120-6775 | CRS-120-6779 | CRS-120-6783 |
120W 80% | 120W 84% | 140W 86% | 140W 86% | 140 87% | 140 87% | |
48Vout | CRS-120-6764 | CRS-120-6768 | CRS-120-6772 | CRS-120-6776 | CRS-120-6780 | CRS-120-6784 |
120 82% | 120W 85% | 140W 88% | 140W 88% | 140W 89% | 140W 89% |
CTS-120 Series
GENERAL FEATURES:
●Designed according to EN50155
●Fire and smoke:EN45545-2 approved
●High input-output isolation
●Standard size Eurocard 3U
●Adjustable output voltage
●Input voltage OK LED
●Output voltage presence LED
●Remote inhibit
●Option:remote sensing or alarm
24Vin 14.4...30V 16.8...30V | 36Vin 21.6...47V 25.2...47V | 48Vin 28.8...60V 33.6...60V | 72Vin 43.2...90V 50.4...90V | 110Vin 66...144V 77...144V | |
5Vout | CTS-120-6865 | CTS-120-6885 | CTS-120-6869 | CTS-120-6873 | CTS-120-6877 |
100W 78% | 100W 79% | 100W 79% | 100W 79% | 100W 80% | |
12Vout | CTS-120-6866 | CTS-120-6886 | CTS-120-6870 | CTS-120-6874 | CTS-120-6878 |
120W 83% | 120W 84% | 120W 84% | 120W 84% | 120W 85% | |
24Vout | CTS-120-6867 | CTS-120-6887 | CTS-120-6871 | CTS-120-6875 | CTS-120-6879 |
120W 84% | 140W 86% | 140W 86% | 140W 86% | 140W 87% | |
48Vout | CTS-120-6868 | CTS-120-6888 | CTS-120-6872 | CTS-120-6876 | CTS-120-6880 |
120W 85% | 140W 88% | 140W 88% | 140W 88% | 140W 89% |
CRS-240 Series
GENERAL FEATURES:
●Switching frequency:140KHz
●High input-output isolation
●Standard size Eurovard 3U
●Adjustable output voltage
●Remote sensing
●Input voltage OK LED
●Output voltage presence LED
●Remote inhibit
12Vin 9...15V | 24Vin 18...30V | 48Vin 36...72V | 72Vin 50.4...90V | 110Vin 77...144V | 220Vin 165...275V | |
5Vout | CRS-240-6351 | CRS-240-6355 | CRS-240-6359 | CRS-240-6363 | CRS-240-6367 | CRS-240-6371 |
180W 79% | 18W 80% | 180W 80% | 180W 81% | 180W 81% | 180W 81% | |
12Vout | CRS-240-6352 | CRS-240-6356 | CRS-240-6360 | CRS-240-6364 | CRS-240-6368 | CRS-240-6372 |
180W 80% | 240W 83% | 240W 84% | 240W 88% | 240W 86% | 240W 86% | |
24Vout | CRS-240-6353 | CRS-240-6357 | CRS-240-6361 | CRS-240-6365 | CRS-240-6369 | CRS-240-6373 |
200W 82% | 240W 87% | 280W 88% | 280W 90% | 280W 91% | 280W 91% | |
48Vout | CRS-240-6354 | CRS-240-6358 | CRS-240-6362 | CRS-240-6366 | CRS-240-6370 | CRS-240-6374 |
200W 82% | 240W 88% | 280W 89% | 280W 90% | 280W 92% | 280W 92% |
CTS-240 Series
GENERAL FEATURES:
●Designed according to EN50155
●Fire and smoke:EN45545-2 approved
●High input-output isolation
●Standard size Eurocard 3U
●Adjustable output voltage
●Input voltage OK LED
●Output voltage presence LED
●Remote inhibit
●Option:remote sensing or alarm
24Vin 14.4...30V16.8...30V | 36Vin 21.6...47V 25.2...47V | 48Vin 28.8...60V 33.6...60V | 72Vin 43.2...90V 50.4...90V | 110Vin 66...144V 77...144V | |
5Vout | CTS-240-6655 | CTS-240-6672 | CTS-240-6659 | CTS-240-6663 | CTS-240-6667 |
180W 80% | 180W 80% | 180W 80% | 180W 81% | 180W 81% | |
12Vout | CTS-24-6656 | CTS-240-6673 | CTS-240-6660 | CTS-240-6664 | CTS-240-6668 |
240W 83% | 240W 83% | 240W 84% | 240W 88% | 240W 86% | |
24Vout | CTS-240-6657 | CTS-240-6674 | CTS-240-6661 | CTS-240-6665 | CTS-240-6669 |
240W 87% | 280W 87% | 280W 88% | 280W 90% | 280W 91% | |
48Vout | CTS-240-6658 | CTS-240-6675 | CTS-240-6662 | CTS-240-6671 | CTS-240-6670 |
240W 88% | 280W 88% | 280W 89% | 280W 90% | 280W 92% |
CRS-500 Series
GENERAL FEATURES:
●Oring FET option
●High input-output isolation
●Adjustable output voltage
●Remote sensing
●Remote inhibit
●Input & Output OK LEDs
●Output failure alarm
●Input reverse polarity protection
●Railway version EN50155
●Fire and smoke:EN45545-2 approved
24Vin 14.4...30V 16.8...30V | 36Vin 21.6...45V 25.2...45V | 48Vin 28.8...60V 33.6...60V | 72Vin 43.2...90V 50.4...90V | 110Vin 66...144V 77...144V | |
24Vout | CRS-500-6455 | CRS-500-6467 | CRS-500-6458 | CRS-500-6461 | CRS-500-6464 |
500W 88% | 500W 88% | 500W 91% | 500W 91% | 500W 91% | |
48Vout | CRS-500-6456 | CRS-500-6468 | CRS-500-6459 | CRS-500-6462 | CRS-500-6465 |
500W 89% | 500 89% | 500W 91% | 500W 91% | 500W 92% |
CRS-1000 Series
GENERAL FEATURES:
●Oring FET option
●High input-output isolation
●Adjustable output voltage
●Remote sensing
●Remote inhibit
●Input & Output OK LEDs
●Output failure alarm
●Input reverse polarity protection
●According to the standard EN50155
●Fire and smoke:EN45545-2 approved
24Vin 14.4...30V 16.8...30V | 36Vin 21.6...45V 25.2...45V | 48Vin 28.8...60V 33.6...60V | 72Vin 43.2...90V 50.4...90V | 110Vin 66...144V 77...144V | |
24Vout | CRS-1000-6475 | CRS-1000-6487 | CRS-1000-6478 | CRS-1000-6481 | CRS-1000-6484 |
1000W 88% | 1000W 89% | 1000W 91% | 1000W 91% | 1000W 92% | |
48Vout | CRS-1000-6476 | CRS-1000-6488 | CRS-1000-6479 | CRS-1000-6482 | CRS-1000-6485 |
1000W 89% | 1000W 90% | 1000W 91% | 1000W 92% | 1000W 93% |
CKR-2000
GENERAL FEATURES:
●Modules series CRS-240/CTS-240
●Module hot swap
●Input and/or output redundancy
●Oring by diodes
●High input-output isolation
●Module Input voltage OK LED
●Module output voltage presence LED
●Module output voltage test point
●Output failure alarm by relay contacts
●Railway version EN50155
B-Sub-rack | A-Modulos/Modules | ||||
Total power | Redun.N+1 | 48Vin(36-60V) | 110Vin(77-144V) | ||
12Vout | NP-9176 | 1920W | 1680W | NP-9179 240W | NP-9182 280W |
24Vout | NP-9177 | 2240W | 1960W | NP-9180 280W | NP-9183 280W |
48Vout | NP-9178 | 2240W | 1960W | NP-9181 280W | NP-9184 280W |
DC-AC
OCS-260 Series
GENERAL FEATURES:
●Sine wave output voltage
●Selectable output frequency:50/60Hz
●Adjustable output voltage
●Output failure alarm
●Remote inhibit
●High input-output isolation 3000Vrms
●Option railway version EN50155
●Fire and smoke:EN45545-2 approved
Model | Input V | Input V range | Output V | Active Power | Apparent Power | Output peak current(10ms) | Effic | No load input current |
7031 | 12Vdc | 9.5...15V | 230Vac | 180W | 260VA | 4Apk | 86% | <0.50A |
7033 | 24Vdc | 16.8...30V | 230Vac | 220W | 260VA | 4Apk | 87% | <0.26A |
7034 | 36Vdc | 25.2...45V | 230Vac | 220W | 260VA | 4Apk | 88% | <0.21A |
7035 | 48Vdc | 33.6...60V | 230Vac | 220W | 260VA | 4Apk | 89% | <0.1** |
7036 | 72Vdc | 50.4...90V | 230Vac | 220W | 260VA | 4Apk | 89% | <0.11A |
7037 | 110Vdc | 77...138V | 230Vac | 220W | 260VA | 4Apk | 90% | <0.08A |
7041 | 12Vdc | 9.5...15V | 120Vac | 180W | 260VA | 8Apk | 85% | <0.50A |
7043 | 24Vdc | 16.8...30V | 120Vac | 220W | 260VA | 8Apk | 87% | <0.26A |
7044 | 36Vdc | 25.2...45V | 120Vac | 220W | 260VA | 8Apk | 88% | <0.21A |
7045 | 48Vdc | 33.6...60V | 120Vac | 220W | 260VA | 8Apk | 88% | <0.1** |
7046 | 72Vdc | 50.4...90V | 120Vac | 220W | 260VA | 8Apk | 88% | <0.11A |
7047 | 110Vdc | 77...138V | 120Vac | 220W | 260VA | 8Apk | 89% | <0.08A |
ODS-750 Series
GENERAL FEATURES:
●Sine wave output voltage
●Selectable output frequency:50/60Hz
●High input-output isolation 3000Vrms
●Three-phase synchronization
●Remote inhibit
●Input and output alarm(optional)
●Railway version EN50155(optional)
●Fire and smoke:EN45545-2 approved
Basic Model | Alarm model | Input voltage | Input voltage range | Output voltage | Active power | Apparent power | Iopk 10ms | Effic | No load input current |
7071 | 7271 | 12Vdc | 9.5...15V | 230Vac | 450W | 750VA | 10A | 85% | 0.80A |
7073 | 7273 | 24Vdc | 16.8...30V | 230Vac | 750W | 750VA | 10A | 86% | 0.46A |
7074 | 7274 | 36Vdc | 25.2...45V | 230Vac | 750W | 750VA | 10A | 87% | 0.36A |
7075 | 7275 | 48Vdc | 33.6...60V | 230Vac | 750W | 750VA | 10A | 88% | 0.27A |
7076 | 7276 | 72Vdc | 50.4...90V | 230Vac | 750W | 750VA | 10A | 88% | 0.17A |
7077 | 7277 | 110Vdc | 77...138V | 230Vac | 750W | 750VA | 10A | 89% | 0.12A |
7081 | 7281 | 12Vdc | 9.5...15V | 120Vac | 450W | 750VA | 16A | 84% | 0.80A |
7083 | 7283 | 24Vdc | 16.8...30V | 120Vac | 750W | 750VA | 16A | 86% | 0.46A |
7084 | 7284 | 36Vdc | 25.2...45V | 120Vac | 750W | 750VA | 16A | 87% | 0.36A |
7085 | 7285 | 48Vdc | 33.6...60V | 120Vac | 750W | 750VA | 16A | 87% | 0.27A |
7086 | 7286 | 72Vdc | 50.4...90V | 120Vac | 750W | 750VA | 16A | 87% | 0.17A |
7087 | 7287 | 110Vdc | 77...138V | 120Vac | 750W | 750VA | 16A | 88% | 0.12A |
ODX-1300 Series
GENERAL FEATURES:
●Sine wave output voltage
●Suitable for motors control
●Adjustable output voltage
●High input-output isolation 3000Vrms
●Remote inhibit
●Remote control via RS232
●Alarm by isolated relay contacts
●Remote ON/OFF opto-coupled
●According to the standard EN50155
●Fire and smoke:EN45545-2 approved
Model | Input | voltage | Max I input | Output voltage | Output power | Output current | Output peak current | Effic | |||
Nom | range | No load | Full load | Nom | range | 10s | 10ms | ||||
Arms | (Iopk) | ||||||||||
7442 | 24Vdc | 16.8...30V | 1.0** | 66A | 250Vac | 150...250V | 1.1kW 1.3kVA | 3.0A | 4.** | 6.4A | 89% |
7445 | 72Vdc | 50...90V | 0.33A | 24.4A | 250Vac | 150...250V | 1.1kW 1.3kVA | 3.0A | 4.** | 6.4A | 90% |
7447 | 110Vdc | 77...140V | 0.20A | 16A | 250Vac | 150...250 | 1.1kW 1.3kVA | 3.0A | 4.** | 6.4A | 90% |
7452 | 24Vdc | 16.8...30V | 1.28A | 66A | 400Vac | 200...400V | 1.1kW 1.3kVA | 1.88A | 2.8A | 4.0A | 89% |
7455 | 72Vdc | 50...90V | 0.39A | 24.4A | 400Vac | 200...400V | 1.1kW 1.3kVA | 1.88A | 2.8A | 4.0A | 91% |
7457 | 110Vdc | 77...140V | 0.2** | 16A | 400Vac | 200...400V | 1.1kW 1.3kVA | 1.88A | 2.8A | 4.0A | 92% |
ODS-1500 Series
GENGRAL FEATURES:
●Sine wave output voltage
●Selectable output frequency:50/60Hz
●Adjustable output voltage
●High input-output isolation 3000Vrms
●Remote inhibit
●Three-phase synchronization
●Remote control via RS232
●Alarm by isolated relay contacts
●Remote off opto-coupled
●Optional railway version EN50155
●Fire and smoke:EN45545-2 approved
Model | Input | Input voltage range | Output voltage | Output power | Output current | Output peak current | Efficiency | |
5s | 10ms(Iopk) | |||||||
7111 | 12Vdc | 10...15V | 230Vac | 1200W | 5.2A | 6.8A | 16A | 87% |
7113 | 24Vdc | 16.8...30V | 230Vac | 1500W | 6.** | 10.0A | 16A | 88% |
7114 | 36Vdc | 25.2...45V | 230Vac | 1500W | 6.** | 10.0A | 16A | 89% |
7115 | 48Vdc | 33.6...60V | 230Vac | 1500W | 6.** | 10.0A | 16A | 90% |
7116 | 72Vdc | 50.4...90 | 230Vac | 1500W | 6.** | 10.0A | 16A | 90% |
7117 | 110Vdc | 77...138V | 230Vac | 1500W | 6.** | 10.0A | 16A | 91% |
7121 | 12Vdc | 10...15V | 120Vac | 1200W | 10.0A | 13.0A | 30A | 86% |
7123 | 24Vdc | 16.8...30V | 120Vac | 1500W | 12.** | 20.0A | 30A | 88% |
7124 | 36Vdc | 25.2...45V | 120Vac | 1500W | 12.** | 20.0A | 30A | 88% |
7125 | 48Vdc | 33.6...60V | 120Vac | 1500W | 12.** | 20.0A | 30A | 89% |
7126 | 72Vdc | 50.4...90V | 120Vac | 1500W | 12.** | 20.0A | 30A | 89% |
7127 | 110Vdc | 77...138V | 120Vac | 1500W | 12.** | 20.0A | 30A | 90% |
ODS-3000 Series
GENERAL FEATURES:
●Sine wave output voltage
●Selectable output frequency:50/60Hz
●Adjustable output voltage
●High input-output isolation 3000Vrms
●Remote inhibit
●Three-phase synchornization
●Remote control via RS232
●Alarm by isolated relay contacts
●Remote off opto-coupled
●Optional railway version EN50155
●Fire and smoke:EN45545-2 apporved
Model | Input | Input voltage range | Output voltage | Output power | Output current | Output peak current | Efficiency | |
5s | 10ms(opk) | |||||||
7153 | 24Vdc | 16.8...30V | 230Vac | 2400W | 10.4A | 1** | 32A | 88% |
7154 | 36Vdc | 25.2...45V | 230Vac | 3000W | 13.0A | 20A | 32A | 90% |
7155 | 48Vdc | 33.6...60V | 230Vac | 3000W | 13.0A | 20A | 32A | 91% |
7156 | 72Vdc | 50.4...90V | 230Vac | 3000W | 13.0A | 20A | 32A | 91% |
7157 | 110Vdc | 77...138V | 230Vac | 3000W | 13.0A | 20A | 32A | 92% |
7163 | 24Vdc | 16.8...30V | 120Vac | 2400W | 20.0A | 28A | 52A | 88% |
7164 | 36Vdc | 25.2...45V | 120Vac | 2500W | 20.8A | 32A | 52A | 89% |
7165 | 48Vdc | 33.6...60V | 120Vac | 2500W | 20.8A | 32A | 52A | 89% |
7166 | 72Vdc | 50.4...90V | 120Vac | 2500W | 20.8A | 32A | 52A | 91% |
7167 | 110Vdc | 77...138V | 120Vac | 2500W | 20.8A | 32A | 52A | 92% |
ODX-3000 Series
GENERAL FEATURES:
●Sine wave output voltage
●Suitable for motors control
●Selectable output frequency:50/60Hz
●Adjustable output voltage
●High input-output isolation 3000Vrms
●Remote inhibit
●Reverse phase
●Remote control via RS232
●Alarm by isolated relay contacts
●Remote off opto-coupled
●Optional railway version EN50155
●Fire and smoke:EN45545-2 approved
Model | Input voltage | Input voltage range | Output voltage | Output power | Output current | Output peak current | Efficiency | |
5s | 10ms(Iopk) | |||||||
7403 | 24Vdc | 16.8...30V | 400Vac | 2400W | 3.46A | 5.2** | 11A | 89% |
7404 | 36Vdc | 25.2...45V | 400Vac | 3000W | 4.33A | 6.6A | 11A | 90% |
7405 | 48Vdc | 33.6...60V | 400Vac | 3000W | 4.33A | 6.6A | 11A | 91% |
7406 | 72Vdc | 50.4...90V | 400Vac | 3000W | 4.33A | 6.6A | 11A | 91% |
7407 | 110Vdc | 77...138V | 400Vac | 3000W | 4.33A | 6.6A | 11A | 92% |
7413 | 24Vdc | 16.8...30V | 230Vac | 2400W | 6.0A | 9.0A | 19A | 89% |
ODX-4500 Series
GENERAL FEATURES:
●Sine wave output voltage
●Suitable motors control
●Selectable output frequency:50/60Hz
●Adjustable output voltage
●High input-output isolation 3000Vrms
●Remote inhibit
●Reverse phase
●Remote control via RS232
●Alarm by isolated relay contacts
●Remote off opto-coupled
●Optional railway version EN50155
●Fire and smoke:EN45545-2 approved
Model | Input voltage | Input voltage range | Output voltage | Output power | Output current | Output peak current | Efficiency | |
5s | 10ms(Iopk) | |||||||
7425 | 72Vdc | 50.4...90V | 400Vac | 4000W/4500VA | 6.** | 9.** | 1** | 91% |
7426 | 100Vdc | 70...125V | 400Vac | 4000W/4500VA | 6.** | 9.** | 1** | 92% |
7427 | 110Vdc | 77...138V | 400Vac | 4000W/4500VA | 6.** | 6.6A | 1** | 92% |
ODX-6000 Series
GENGRAL FEATURES
Sine wave output voltage
Suitable for motors control
Adjustable output frequency
Adjustable output voltage
High input-output isolation 3000Vrms
Remote off opto-coupled
Alarm by isolated relay contacts
Rotation inversion
Remote control via RS232
CAN BUS(optional)
Railway inversion EN50155(optional)
Fire and smoke:EN45545-2 approved
Efficiency up to 93%
ODX-6000 | 24Vdc 16.8...30V | 48Vdc 33.6...60V | 72Vdc 50.4...90V | 110Vdc 77...138V |
400Vac | ODX-6000-7503 | ODX-6000-7505 | ODX-6000-7506 | ODX-6000-7507 |
4500W | 6000W | 6000W | 6000W |
UPS-DC
ECT-100 Series
GENERAL FEATURES:
●Battery cut off when battery low
●Battery constant current charging
●4 Selectable current charging levels
●Step mains to battery without voltage dips
●Independent alarms of supply fail and battery low
●Battery not included
Models | Battery | Charging current selection | ||||||
ECS-100- | current | Nominal | Floating | Cut off | I1 | I2 | I3 | I4 |
5073 | 7.3** | 12V | 13.6V | 10V | 0.** | 0.6A | 1.2A | 2.4A |
5077 | 3.68A | 24V | 27.2V | 20V | 0.2** | 0.3A | 0.6A | 1.2A |
5079 | 1.84A | 48V | 54.4V | 40V | 0.11A | 0.1** | 0.3A | 0.6A |
5173 | 7.3** | 12V | 13.6V | 10V | 1.0A | 1.2A | 2.4A | 4.8A |
5177 | 3.68A | 24V | 27.2V | 20V | 0.** | 0.6A | 1.2A | 2.4A |
5179 | 1.84A | 48V | 54.4V | 40V | 0.22A | 0.3A | 0.6A | 1.2A |
ECT-200 Series
GENERAL FEATURES:
●Battery cut off when battery low
●Battery constant current charging
●4 Selectable current charging levels
●Step mains to battery without voltage dips
●Independent alarms of supply fail and battery low
●Parallel connection allowable (24 and 48V output)
●Battery not included
Models | Battery | Charging current selection | ||||||
ECS-200- | Current | Nominal | Floating | Cut off | I1 | I2 | I3 | I4 |
5083 | 14.7A | 12V | 13.6V | 10V | 1.0A | 1.2A | 2.4A | 4.8A |
5087 | 8.3A | 24V | 27.2V | 20V | 0.** | 0.6A | 1.2A | 2.4A |
5089 | 4.2A | 48V | 54.4V | 40V | 0.22A | 0.3A | 0.6A | 1.2A |
5183 | 14.7A | 12V | 13.6V | 10V | 2.0A | 2.4A | 4.8A | 9.6A |
5187 | 8.3A | 24V | 27.2V | 20V | 1.0A | 1.2A | 2.4A | 4.8A |
5189 | 4.2A | 48V | 54.4V | 40V | 0.44A | 0.6A | 1.2A | 2.4A |
EDT-150-12
The EDT-150-12V is a charger-rectifier to 12V batteries capable of charging
up to 40Ah capable lead-acid batteries. The overall power output that may be
supplied is 150W permanently and 275W for 10 second each minute.Input voltage
is 230Vac.
INPUT(AC Power Supply)
Mains input voltage 230Vac
Mains input voltage range -20%...+15%
Mains input frequency range 47...63Hz
DC OUTPUT 1 2 3
Rated output voltage 13.6 48 48 V
Maximum continuous current 15.7 3.2 0.83 A
Peak current(10sec each minute) 26 4.2 0.83 A
CHARGER
Type of battery Sealed lead-acid
Rated battery voltage 12V
Battery capacity 38Ah
Battery
The equiment has an automic,periodic batter status testing system.
Communication
Carried out via Ethernet
The system has the following characteristics:
●Compatibility with IPV4 with automatic IP (DHCP) assignment
●Web services:Load XML files,firmaware and websites
●Check/modify firmware,alarms and configuration remotely from a website
●User authentication using LDAP
●Time synchronization using SNTP protocol
EPS-120-48
The EPS-120-48V is a charger-rectifier for 48V batteries capable of
charging 1Ah to 1**h capacity lead-acid batteries.The overall power
output that may be supplied is 120W permanently and 180W for 10
seconds each minute.Input voltage is 230Vac.
INPUT(AC Power Supply)
Mains input voltage 230Vac
Mains voltage range -20%...+15%
Mains frequency range 47...63Hz
DC OUTPUT 1
Rated output voltage 48 V
Maximum continuous current 3.077 A
Peak current(10sec each minute) 4.61 A
CHARGER
Type of battery Sealed lead-acid
Rated battery voltage 48V
Battery capacity 1Ah-1**h
ISOLATION
ISOLATION | LEVEL | Standard |
AC terminal,active parts and earth,industrial frequency | 10kVac | UNE EN60255-5 |
AC terminal,between active parts and earth,industrial frequency | 10kVac | UNE EN60255-5 |
AC terminal,active parts and earth,lightning impulse | 20kV | UNE EN60255-5 |
AC terminal,active parts,lightning impulse | 20kV | UNE EN60255-5 |
DC terminal,industrial frequency | 2.5kVac | UNE EN60255-5 |
DC terminal,lightning impulse | 5kV | UNE EN60255-5 |
COMMUNICATION
Carried out via Ethernet.
This system has the following characteristics:
●Compatibility with IPV4 with automatic IP(DHCP) assignment
●Web Services:Load XML files,firmware and websites
●Check/modify firmware,alarms and configuration remote from a website
●User authentication using LDAP
●Time synchronization using SNTP protocol
EPS-200-48V
The EPS-200-48 is a charge-rectifier for 48V batteries capable of charging 10Ah to 20Ah
capacity lead-acid batteries.the overall power output that may be supplies is 200W permanently
and 400W for 10 seconds each mintue.Input voltage is 230Vac.
INPUT(AC Power Supply)
Mains input voltage 230Vac
Mains voltage range -20%...+15%
Mains frequency range 47...63Hz
DC OUTPUT 1
Rated output voltage 48V
Maximum continue current 5.2A
Peak current(10sec each mintue) 10.3A
CHARGER
Type of battery Sealed lead-acid
Rated battery voltage 48V
Battery capacity 10Ah-20Ah
ISOLATION
ISOLATION | Level | Standard |
AC terminal,active parts and earth,industrial frequency | 10kVac | UNE EN60255-5 |
AC terminal,between active parts and earth,industrial frequency | 10kVac | UNE EN60255-5 |
AC terminal,active parts and earth,lightning impulse | 20kV | UNE EN60255-5 |
AC terminal,active parts,lightning impulse | 20kV | UNE EN60255-5 |
DC terminal,industrial frequency | 2.5kVac | UNE EN60255-5 |
DC terminal,industrial impulse | 5kV | UNE EN60255-5 |
Battery Test
The equipment has an automatic,periodic battery status testing system.
ALARMS
There are 4 alarm output by potential free contacts with the following characteristics:
●Maximum switchable voltage 60Vdc
●Maximum current:100mA
Name of alarm | Status | Operating logic |
Urgent malfunction | NC | In normal operation the charger is open It remains closed upon battery or internal equipment malfunction. |
End of battery life | NA | It closes when the battery is discharging and the voltage drops to its minimum preset value. |
Non-urgent malfunction | NA | It closes when output voltage is out of range,the battery or internal temperature is out of range. |
Mains malfunction | NA | It closes if the mains AC voltage is out of margin. |
COMMUNICATION
Carried out via Ethernet.
This system has the following characteristics:
●Compatibility with IPV4 with automatic IP (DHCP) assignment
●Web Services:Load XML files,firmware and websites
●Check/modify firmware,alarms and configuration remotely from a website
●User authentication using LDAP
●Time synchronization using SNTP protocol
CONFIGURATION
Basic equipment configuration is carried out via the Ethernet port.
The following parameters are configurable:
●Floating voltage
●Chargeing voltage compensation with temperature
●Maximum charging current
●Through to float current
●Maximum time at Constant voltage
●Battery disconnection:Minimum voltage
●Battery disconnection:Maximum voltage
●Battery disconnection:Minimum immediate disconnection voltage
●Battery test:Time between testing cycles
●Battery test:Voltage limit for test failure
●Battery discharge capacity
●Battery test:Time limit for each test attempt
●Battery test:Num. of retries
●Output voltage:Minimum value
●Output voltage:Maximum value
●Overload:Num. of connection retries
●Overload:Time between retries
如需更多的产品资料,请随时联系我:021-64608192 sales@ruilvpower.cn。